Working Space - Code Minimum
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel points out the dimensions of empty working space required by the National Electrical Code (NEC) for electrical servicing. While the space is a straightforward “box” of linear measurements, there are some additions to the code, including foreign fluid protections and electrical equipment & structural exemptions, which every electrician should know as well.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Stanley FATMAX Tape Measure: https://www.homedepot.com/p/Stanley-25-ft-FATMAX-Magnetic-Tape-Measure-FMHT33865L/203751294#overlay
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Working space requirements [NEC 110.26]
Outline:
0:00 - Introduction
0:31 - Wall Space
0:49 - Floor Space
1:07 - Vertical Space
1:40 - Related Electrical Equipment Exceptions
2:22 - Foreign Fluid Systems Protection
3:04 - Structural Exceptions
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
4
views
5 Common Electrical Panel Mistakes
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel continues to highlight some best practices pertaining to electrical panels and some errors left behind by a previous sub-contractor, particularly an incompatibility breaker, debris inside the panel, and mediocre mounting practices.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Blunt, machine-threaded screws: https://www.homedepot.com/p/8-32-x-7-8-in-Zinc-Combo-Drive-Truss-Head-Machine-Thread-1000-per-Box-0-TCM0832078Z/304754293
[] Electrical Panel Cable Clamp Connectors (Available in different sizes): https://www.homedepot.com/p/Halex-3-8-in-Non-Metallic-NM-Twin-Screw-Cable-Clamp-Connectors-5-Pack-20511/100133208?MERCH=REC-_-searchViewed-_-NA-_-100133208-_-N&#product-overview
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Electrical Equipment Listing & Labeling [NEC 110.3(B)]
Outline:
0:00 - Introduction
0:12 - Breaker Compatibility
0:38 - Foreign Objects
0:59 - Bushings (Good & Bad)
2:08 - Proper Cover Fasteners
2:54 - Proper Panel Mounting
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
14
views
Wiring an Electrical Panel 101
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel looks into a secondary electrical panel and highlights the safety and organizational decisions that all electrical professionals and DIYers should make routine. Covering and labelling the box, ensuring proper electrical connections, and a couple tricks of the trade employed daily by Jefferson Electric masters, journeymen, & apprentices can give you the confidence to master this power hub in your home.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] iDEAL NOALOX Anti-Oxidant Compound: https://www.homedepot.com/p/NOALOX-4-oz-Anti-Oxidant-Compound-30-026/202276208
[] Neiko 1/4" Adjustable Torque Screwdriver Set: https://www.amazon.com/dp/B000RZ1D86/ref=cm_sw_r_cp_apip_h5fnqFLwyFzBi
[] Neiko 3/8" Adjustable Torque Wrench: https://www.amazon.com/dp/B000N7AWRG/ref=cm_sw_r_cp_apip_dwFnQNdVjOLXk
[] Neiko 3/4" Digital Torque Adaptor: https://www.amazon.com/dp/B009GLITFW?tag=plumbaroaklan-20&linkCode=osi&th=1&psc=1&keywords=3%2F4%20Torque%20Wrench
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Electrical Panel Boxes [NEC 408]
[] Grounding and Bonding Table for quick reference [NEC 250.3]
Outline:
0:00 - Introduction & Safety
1:45 - Intermediary Labeling
3:00 - Proper Termination
5:00 - Secondary Panel Wiring
6:50 - Localized Piping Systems
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
14
views
Does a Basement Bedroom Get Special Electrical Treatment?
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel continues the punch-out of the downtown Indianapolis home by turning from the utility room to a nearby basement bedroom. All the same code standards apply as long as the bedroom has the same features as an upstairs bedroom. Joel will point out the defining characteristics of a bedroom and the necessary electrical outlets for the room.
Joel will also take a moment within the technical instruction to recommend some points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Bosch Laser Measure: https://www.homedepot.com/p/Bosch-BLAZE-165-ft-Green-Laser-Distance-Tape-Measuring-Tool-with-Color-Screen-and-Measurement-Rounding-Functionality-GLM165-25G/316141208
[] Kidde Smoke Detector: https://www.homedepot.com/p/Kidde-Firex-Smoke-Detector-Hardwired-with-Battery-Backup-Front-Load-Battery-Door-Smoke-Alarm-21029877/202029419
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Receptacle outlet spacing [NEC 210.52]
Outline:
0:00 - Introduction & Lighting
0:34 - Bedroom definition
0:47 - Electrical requirements
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
9
views
Water Heater and Sump Pump Outlets
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel takes a look at some heavy-load, water-related equipment: Water heaters & sump pumps. These kinds of equipment require a dedicated receptacle and GFCI protection for safety purposes. In some cases, fully-electric, heavy-load equipment may require a 30-amp feed and thicker wire gauge from the electrical box. Be sure to install a water level and power failure monitor for appliances that pose a flood risk.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Hubbell 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] Hubbell 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
[] 30 Amp Double Pole Ground Fault Breaker with Self-Test: https://www.homedepot.com/p/GE-30-Amp-Double-Pole-Ground-Fault-Breaker-with-Self-Test-THQL2130GFTP/206602329
[] Moen Flo Water Detector (Ground level): https://www.amazon.com/dp/B0855BFQCZ
[] Superior Pump Sump/Sewage Alarm System (Float Switch): https://www.homedepot.com/p/Superior-Pump-Sump-Sewage-Alarm-System-92060/206496506?MERCH=REC-_-pip_alternatives-_-202216508-_-206496506-_-N#product-overview
[] Power Failure Alarm: https://www.amazon.com/PFA-1-Power-Failure-Alarm/dp/B005VDPE3O
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] GFCI Protection [NEC 210.8(A)]
[] Serviceable Equipment Receptacle Requirements [NEC 210.63]
[] Wire gauge requirement for 30-amp service [240.4(B)(7)]
Outline:
0:00 - Introduction
0:08 - Water Heater Electrical
1:26 - Sump Pump Electrical
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
10
views
Basement Electrical - Code Minimum
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel walks through the living spaces and unfinished spaces of a newly constructed home, clarifying the electrical needs of each space. The NEC makes more of its distinctions based on the presence of certain equipment, water, or foot traffic in a room or space, rather than the location in the house. This is particularly true in a basement, where the amount of finishing will vastly change the electrical requirements.
Joel will also include some recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Hubbell 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] Hubbell 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Receptacle Outlet Requirements [NEC 210.52-65]
Outline:
0:00 - Introduction
0:08 - Basement Living Space
4:56 - Utility Room
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
8
views
Outdoor Power - Code Minimum
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel gives a look inside a project assignment at Jefferson Electric before breaking down outdoor electrical code.
JE recommends thorough front-end communication and access to a communication software that allows for on-site feedback and leadership trust & mobility amongst multiple job sites. A team should be a body of different parts that value and honor one another equally.
The codes for outdoor spaces are often dependent on landmarks, like the front door and the AC unit; however, it is always important to remember that the code represents a minimum requirement, not necessarily optimal accessibility. If considering extensive yard lighting, pool equipment, a patio with electric cooking appliances, or other outdoor scenes, make sure to reach out to a local professional for power recommendations.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Slack Pro Software: https://slack.com/
[] Hubbell 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] Hubbell 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
[] Exterior In-Use Receptacle Cover: https://www.homedepot.com/p/Commercial-Electric-Clear-1-Gang-Extra-Duty-Non-Metallic-While-In-Use-Weatherproof-Horizontal-Vertical-Receptacle-Cover-WCW1PC/300849073
National Electrical Code (NEC) referenced in this video:
The NEC is the standard for all Jefferson Electric masters, journeymen, & apprentices.
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Receptacle faces shall be flush with or extend from the faceplate [NEC 406.4(D)]
Outline:
0:00 - Introduction
1:19 - Exterior Code
2:24 - HVAC Service
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
14
views
Outlet Receptacle Spacing - Code Minimum
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel demonstrates how to save time, effort, and money while also wiring receptacles throughout a 4-story home “to code”. A quality wiring project will reduce service costs and stress down the road. Joel will summarize the National Electrical Code (NEC) in standard living spaces, and several unusual spaces in a newly built home in downtown Indianapolis, including fixed cabinetry and non-mountable fixed wall space.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] 20-Amp GFCI Pop-Up Floor Box: https://www.homedepot.com/p/Leviton-Pop-Up-Floor-Box-with-20-Amp-Tamper-Resistant-Self-Test-GFCI-Outlet-Brushed-Nickel-PFGF2-BN/309998635
[] 15-Amp Receptacle Pop-Up Floor Box: https://www.homedepot.com/p/Leviton-Pop-Up-Floor-Box-with-15-Amp-Tamper-Resistant-Outlet-Bronze-PFTR1-BZ/309998652
[] Hubbell 15-Amp Outlet Receptacle: https://www.lowes.com/pd/Hubbell-X-Clamp-White-15-Amp-Duplex-Tamper-Resistant-Outlet-Residential-Outlet/1000275845
[] Hubbell 20-Amp Outlet Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Duplex-Tamper-Resistant-Weather-Resistant-Outlet-Residential-Commercial-Outlet/1000049921
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Receptacle Requirements & Spacing [NEC 210.50-210.65]
Outline:
0:00 - Introduction
0:54 - Living Spaces
2:25 - Fixed Panels & Doors
4:00 - Cabinetry & Irregular Wall Space
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
23
views
Pre-Crew Electrical Walkthrough
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel verifies a contractor’s call that a job site is “ready for an electrical team”. In this particular case, the site is not quite ready, but Joel can still make preparations for a future team.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] King Sharpie: https://www.amazon.com/Sharpie-15661PP-Permanent-Marker-4-Count/dp/B0013CQ20Q/ref=sr_1_3?dchild=1&keywords=king+sharpie&qid=1628097519&sr=8-3
National Electrical Code (NEC):
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
Outline:
0:00 - Introduction
0:25 - HVAC & Plumbing Interference
0:55 - Layout Notes
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
3
views
Garage Wiring - Code Minimum
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel prepares for a garage wiring by reviewing the relevant electrical code to a standard garage layout. He also considers the implications of various security measures, electrical access for power tools at a workbench, and indoor & outdoor lighting.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Linear LEDs: https://www.lowes.com/pd/GE-LED-40-Watt-EQ-48-in-Daylight-Linear-LED-Tube-Light-Bulb-2-Pack/1002643020
[] 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Outdoor Branch Circuits [NEC 225]
[] Garage Branch Circuits [NEC 210.52(G)]
[] Required Garage Lighting [NEC 210.70(A)(2)(2)]
Outline:
0:00 - Introduction
0:28 - Powered Garage Minimums
1:26 - Homeowner Safety Tip
2:06 - Wiring Recommendations
3:36 - Lighting Recommendations
4:56 - Workbench Considerations
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
18
views
A Master Electrician's Site Prep - Part 4
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Given the nature of the trades, communication between coworkers, contractors, and customers can be incredibly different and difficult. In this video Joel, highlights some universal truths of relationships that will simplify the variation between different audiences & partners. These tricks and tools are employed daily by Jefferson Electric masters, journeymen, & apprentices in the city of Indianapolis, IN.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
Outline:
0:00 - Introduction
0:18 - Precision Language
2:40 - Value-Added Language
3:52 - Physical Appearance
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
4
views
A Master Electrician's Site Prep Part 3
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel tells the story of a young lead electrician who had to own up to a mistake. In any job or trade, integrity often dictates the health and reputation of the company. While painful in the moment, mistakes, honesty, and integrity can be catalysts for growth. Integrity is 1 of 3 core values of Jefferson Electric (alongside Excellence & Relationships) which differentiate it from the competition.
If this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
Outline:
0:00 - Introduction
0:25 - Defining Integrity
0:49 - True Story
3:06 - Conclusion
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
8
views
A Master Electrician's Keys to Success - Part 2
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel shares more of his keys to success on the job site and in a management role. Details are what set an excellent electrician apart from an average electrician, and the attitudes and mentalities that a person puts toward relationships and tasks can gradually lead to massive differences in customer, co-worker, and business satisfaction. Jefferson Electric’s rapid growth, glowing customer reviews, and positive workplace environment attest to the quality of these standards.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
Outline:
0:00 - Introduction
0:19 - Software
0:41 - Thoroughness & Persevearance
2:21 - Relationships
4:07 - Feedback
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
2
views
A Master Electrician's Keys to Success - Part 1
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel lays out some of the basics of a master electrician’s preparation for large-scale projects, including contract deliverables and the importance of scheduling.
These are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
Outline:
0:00 - Introduction & Background
1:07 - Contracting
1:47 - Scheduling
2:22 - Walkthrough
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
2
views
GFCI Crash Course - Part 2
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel takes a pause from tutorials to highlight the many uses and requirements surrounding GFCI outlets, and how a master electrician efficiently puts them to use. See below for a link to the National Fire Protection Association’s (NFPA) National Electrical Code (NEC).
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Hubbell 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] Hubbell 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] GFCI protection [NEC 210.8]
Outline:
0:00 - Introduction
0:18 - Required GFCI Spaces
1:47 - Example GFCI Circuit
2:59 - Not Required GFCI Spaces
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
5
views
Outlet Remodel In Old Wooden Walls
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel addresses the main fire hazard when rewiring an old home with plaster and lath walls. The solution is quick, cheap, and easy for any homeowner, contractor, or electrician to remediate. Finally, Joel will give some quick recommendations for finishing touches.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Electrical Box Extender: https://www.homedepot.com/p/Electrical-Box-Extender-BE1-2/202708650
[] #6-32 x 1-1/4 in. Phillips Flat Head Zinc Plated Machine Screw (25-Pack): https://www.homedepot.com/p/Everbilt-6-32-x-1-1-4-in-Phillips-Flat-Head-Zinc-Plated-Machine-Screw-25-Pack-802142/204325628
National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Flush mounted boxes and receptacles [NEC 314.20]
[] Securing boxes [NEC 314.23]
[] Mounting receptacles [NEC 406.5]
Outline:
0:00 - Introduction
1:20 - Installing a Box Extender
2:47 - Drywall Inspection & Corrections
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
20
views
Installing a Wired Smoke Detector
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel installs a Kidde FireX smoke detector while explaining the complexities and requirements of the Authority that Has Jurisdiction (AHJ).
A smoke detector is a simple installation requiring a few wire nuts, a screwdriver, and maybe a pair of lineman's pliers.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Kidde Smoke Detector: https://www.homedepot.com/p/Kidde-Firex-Smoke-Detector-Hardwired-with-Battery-Backup-Front-Load-Battery-Door-Smoke-Alarm-21029877/202029419
[] Klein Linemans Pliers: https://www.amazon.com/Linemans-Crimping-Klein-Tools-J2000-9NECRTP/dp/B0026TFRQ0
National Electrical Code (NEC) referenced in this video:
Smoke detectors are not covered by the National Electrical Code (NFPA 70). See your state or local codes and requirements.
Outline:
0:00 - Introduction
0:17 - Unboxing
0:50 - Preparation
1:32 - Code & AHJ
3:00 - Wiring
4:40 - Mounting
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
19
views
Installing a 3 Gang Switch Box
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Despite their spaciousness, 3-gang switch boxes can be a headache of organization and a future hazard if not arranged with thought and care. Joel breaks down a master electrician’s plan of attack to conquer the challenge from the outset and avoid a tangled, fire-starting wire monster living in your walls!
Specifically, Joel addresses identifying and understanding many different wire ends, orienting switches, distributing a hot feed with a pigtail, wire nut troubleshooting, fitting multiple devices into one box, and proper mounting of switches to the box.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Milwaukee Wire Strippers: https://www.homedepot.com/p/Milwaukee-7-in-Wire-Strippers-48-22-6109/206865419
[] Tongue & Groove Pliers (AKA Channel Locks): https://www.lowes.com/pd/IRWIN-Quick-Adjusting-GrooveLock-VISE-GRIP-2-Pack-Tongue-Groove-Plier-Set/1003142306
[] 14-2 Romex: https://www.homedepot.com/p/Southwire-25-ft-14-2-Solid-Romex-SIMpull-CU-NM-B-W-G-Wire-28827421/202316376
[] 3-Gang Electrical Box (Pre-Drywall): https://www.homedepot.com/p/Carlon-3-Gang-44-cu-in-New-Work-PVC-Electrical-Outlet-Box-B344AB/100404028?MERCH=REC-_-pipinstock-_-203634436-_-100404028-_-N
[] 3-Gang Electrical Box (Post-Drywall): https://www.homedepot.com/p/Carlon-3-Gang-55-cu-in-Old-Work-PVC-Electrical-Box-B355R/100211759?MERCH=REC-_-pipinstock-_-203634436-_-100211759-_-N&
[] 3-Gang Switch plate: https://www.homedepot.com/p/Leviton-White-3-Gang-Toggle-Wall-Plate-1-Pack-R52-00PJ3-00W/100356915
[] Wire Nuts (Tan): https://www.amazon.com/Ideal-30-341-Twister-Wire-Connector/dp/B00R8MQ0FM
National Electrical Code (NEC) referenced for this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Mounting of general-use switches, dimmers, & control switches [NEC 404.10]
Outline:
0:00 - Introduction
0:23 - Identifying wires
0:44 - Grounding multiple devices on 1 wire
1:56 - Correctly terminating switch legs
3:40 - Pigtailing a hot feed
8:08 - Mounting switches to the box
9:56 - Straightening switches & installing wall plate
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
21
views
Code Related to Countertops
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel takes a break from installations to flesh out the many code requirements surrounding kitchens, countertops, and islands & peninsulas, including spacing, height, quantity, waterproofing, and more.
While interpreting the technical language of the National Electrical Code (NEC), Joel will also make some recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices that set them apart in their local competitive market of Indianapolis, IN.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] National Fire Protection Agency’s (NFPA) National Electrical Code (NEC): https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Legrand Adorne 15-Amp Pop-Out Outlet: https://www.lowes.com/pd/Legrand-adorne-White-15-Amp-Square-Tamper-Resistant-with-Wall-Plate-Outlet-Residential-Pop-Out-Outlet/1000955980
[] Link2Home Space Saver Pop-Up Outlet: https://www.homedepot.com/p/Link2Home-Space-Saver-Pop-Up-Outlet-3-Power-Outlets-15-Amp-2-USB-Ports-2-4-Amp-Overload-Protection-Splash-Resistant-EM-PU-100E/311530223
[] Leviton Pop-Up GFCI Outlet: https://www.homedepot.com/p/Leviton-Pop-Up-Floor-Box-with-20-Amp-Tamper-Resistant-Self-Test-GFCI-Outlet-Brushed-Nickel-PFGF2-BN/309998635
National Electrical Code (NEC) referenced in this video:
[] Required receptacle outlets [NEC 210.50 & surrounding sections]
[] Dwelling Unit Receptacle outlets services countertops & work surfaces[NEC 210.52(C) & surrounding sections]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
14
views
Installing a Light over the Kitchen Sink
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel attempts to wire & mount a light fixture to a pancake box above the sink. Not only does he need to maneuver over the counters that are partially installed, but Joel will also need to carefully connect stranded wire to the home’s Romex and pack all wires tighter into the wall than usual due to the pancake box.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] 1-Gang Steel Pancake Box: https://www.lowes.com/pd/RACO-1-Gang-Gray-Steel-New-Work-Standard-Ceiling-Fan-Ceiling-Electrical-Box/3129641
[] Assorted Wire Nuts (Depending on fixture gauge): https://www.lowes.com/pd/IDEAL-Assorted-WingTwist-25-Pack-Multi-Wire-Connectors/3128789
[] Rustic Light Feature: https://www.homedepot.com/p/1-Light-Imperial-Black-Outdoor-Wall-Mount-Barn-Light-Sconce-EL0424IB/304280934
National Electrical Code (NEC) referenced in this video:
[] Grounding metal components [NEC 250.148]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
6
views
GFCI Crash Course
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel briefly offers some tips and facts relating to GFCI outlet receptacles, including code requirements & best use.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] Hubbell 15-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-15-Amp-Decorator-Tamper-Resistant-Outlet-GFCI-Residential-Commercial-Outlet/1000050025
[] Hubbell 20-Amp GFCI Receptacle: https://www.lowes.com/pd/Hubbell-White-20-Amp-Decorator-Outlet-GFCI-Residential-Commercial-Outlet/1000814860
National Electrical Code (NEC) referenced in this video:
[] GFCI protection [NEC 210.8]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
3
views
Installing Two Single Pole Switches
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel walks through how a master electrician navigates and organizes a busy 2-gang electrical box.
In this particular case, Joel is installing 2 single pole switches for an over-sink light & the garbage disposal. He’ll cover combining ground wires by crimping to save space, pre-twisting and capping wires in a wire nut, clearing paint or primer off of wire ends, “pigtailing” one hot wire for 2 hot feeds, & packing & covering an electrical box. Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
[] 15-Amp Single Pole Switch: https://www.lowes.com/pd/Utilitech-15-Amp-Single-Pole-White-Framed-Toggle-Light-Switch-10-Pack/5001930233
[] Copper Crimp Sleeves: https://www.amazon.com/Easy-Twist-Copper-Sleeve-Connector-Blister/dp/B00CTU6TI6
[] Klein Tools Linemans Pliers: https://www.amazon.com/Linemans-Crimping-Klein-Tools-J2000-9NECRTP/dp/B0026TFRQ0
[] Red Wire Nuts (Recommended for 4 x 12-gauge wires): https://www.amazon.com/Ideal-30-452-Wing-Nut-Wire-Connector/dp/B014HBITIW
[] 2-Gang Switch Wallplate: https://www.amazon.com/Leviton-80709-W-2-Toggle-Standard-Smooth/dp/B000H5XT06
National Electrical Code (NEC) referenced in this video:
[] Cover plates shall completely cover the opening [NEC 406.5]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
27
views
1
comment
Terminating a Receptacle Outlet
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel breaks down a master electrician’s thought process and mounting of a new outlet receptacle to previously run/existing wiring.
In this particular case, Joel encounters 2 unique obstacles: Clearing excessive drywall mud from an electrical box and identifying & manipulating an adjustable in-wall electrical box.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Thank you for watching; we value your feedback and actively monitor this channel.
Products We’d Recommend:
- Non-Contact Voltage Detector: https://www.amazon.com/Dual-Range-Contact-Klein-Tools-NCVT-5/dp/B07FNJHCP9
- 15-Amp Outlet Receptacle: https://www.lowes.com/pd/Eaton-White-15-Amp-Duplex-Tamper-Resistant-Residential-Outlet/1001464140
- Dewalt Electric (Battery) Oscillator: https://www.amazon.com/DEWALT-DCS356B-Variable-Oscillating-Multi-Tool/dp/B07VBB55X5
- Universal Oscillator Blades: https://www.amazon.com/Vtopmart-Oscillating-Multitool-Multimaster-Craftsman/dp/B07C3RRV8T
National Electrical Code (NEC) referenced in this video:
- Receptacle faces shall be flush with or extend from the faceplate [NEC 406.4(D)]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc
7
views
Installing a GFCI
Electric Pro Academy - Real Skills to make real money.
Synopsis:
Joel breaks down a master electrician’s thought process and mounting of a new GFCI outlet receptacle to previously run/existing wiring. Besides routine installation, Joel explains what a GFCI is, & offers tips for when to use one and what to do if an electrical box is recessed back into the wall.
Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
- 20-Amp GFCI Outlet Receptacle: https://www.homedepot.com/p/Leviton-20-Amp-Self-Test-SmartlockPro-Slim-Duplex-GFCI-Outlet-White-R12-GFNT2-0RW/205996739
- Milwaukee 9.5 in. Crimping Pliers: https://www.homedepot.com/p/Milwaukee-9-5-in-Crimping-Plier-48-22-6103/206541168
- Klein Square 1 & 2 Screwdriver: https://www.homedepot.com/p/Klein-Tools-2-in-1-Insulated-Flip-Blade-Screwdriver-1-Square-2-Square-32287/311525924
- #6-32 Hex Nut: https://www.homedepot.com/p/Hillman-Stainless-Machine-Screw-Hex-Nut-6-32-956/204794879
- Outlet box spacers (Alternate method for receptacle spacing): https://www.homedepot.com/p/Smart-Fill-Spacers-1-4-in-1-Gang-Outlet-Box-Spacer-Extender-5-Pack-SG14-5/307424539
- Mr. Clean Magic Erasers: https://www.amazon.com/Clean-Erase-Renew-Eraser-Original/dp/B006K3Q9IS
National Electrical Code (NEC) referenced in this video:
- GFCI (Ground-Fault Circuit-Interrupter protection for personnel) [NEC 210.8]
- 3" minimum length of conductors extending from the finished surface [NEC 300.14]
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/
12
views
Three Way Switch Wiring
Electric Pro Academy - Real Skills to make real money.
• Before getting into the wiring check that the power it turned off using a non-contact voltage tester (link below). Make sure to test the tool on a known live circuit right before testing the wires to be worked.
• In switching applications the white wire isn't always a neutral wire. If it is part of the switched hot it must be "durably marked" generally with a flag of colored electrical tape (red, blue, brown, black, yellow are all acceptable).
• Mechanical connectors (crimp sleeves, wire nuts etc) are required by code for all wire connections.
• Code requirement to clean off the conductors (stripped ends of the wire) - clean off paint or wall mud using the correctly sized hole in your stripping tool.
• Always use the screw tightened fittings on the switch, push in connectors are not quality connections - wrap the wire around the screw in a CLOCKWISE direction, so the tightening of the screw pulls the wrapped wire in tightly.
• Tuck and fold the wires into the wire box - watch the location of the grounding conductor and make sure that it doesn't get any where near the switch terminals or other bare conductors.
• Secure but don't over tighten the switch so that it deforms.
• Make sure the box is within 1/4" of the surface of the drywall.
• Install the switch cover - finish by orienting the screw slot in a consistent direction.
Got a question or ideas for a video leave and comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Products:
• https://www.homedepot.com/p/Leviton-15-Amp-Single-Pole-Toggle-Light-Switch-White-R52-01451-02W/100026991
• https://www.homedepot.com/p/Klein-Tools-Dual-Range-Non-Contact-Voltage-Tester-with-Flashlight-12-Volt-to-1000-Volt-AC-NCVT-3PR/312665549
• https://www.homedepot.com/p/Milwaukee-7-75-in-Combination-Electricians-6-in-1-Wire-Strippers-Pliers-48-22-3079/202966263
115