Program SiXMINICT to Lyric Controller
In this video, Michael from Alarm Grid shows you how to program a Honeywell SiXMINICT to a Honeywell Lyric Alarm System. The Honeywell SiXMINICT is a compact door and window contact sensor that is used with the Honeywell Lyric Controller. It lets the system know when a door or window is opened. This is done using the main sensor and an accompanying magnet. The sensor goes on the door or window frame, while the magnet goes on the moving portion of the door. The magnet should be within a half-inch of the sensor for reliable performance.
The Honeywell SiXMINICT is a more compact version of the Honeywell SiXCT, which is used for the same purpose. The Honeywell SiXCT offers a better wireless range than the SiXMINICT (300 nominal feet vs. 200 nominal feet). And unlike the SiXMINICT, the standard SiXCT has a terminal block for connecting a wired contact so that the SiXCT can operate as a wireless transmitter on behalf of the connected sensor. But the advantage to the SiXMINICT is that it is considerably smaller and less noticeable than the SiXCT. The compact nature can be very important for some users, especially when it is a sensor as prominent as a surface-mounted door and window contact.
As the Honeywell SiXMINICT is part of the Honeywell SiX Series Lineup, the sensor can only be used with the Honeywell Lyric Alarm Panel. It will not work with any other panels. The sensor uses 128-bit AES encryption for enhanced wireless security and protection. There is a green LED light on the Honeywell SiXMINICT that is used for enrollment purposes. When the light is blinking quickly, it means that the SiXMINICT is not actively enrolled with a Lyric System. But if the LED is blinking slowly, then the sensor is currently paired.
https://www.alarmgrid.com/faq/how-do-i-program-a-honeywell-sixminict-to-the-lyric-security-sys
-
8:42
Alarm Grid Home Security DIY Videos
3 years agoProgram SiXCT to Lyric Controller
17 -
8:49
Alarm Grid Home Security DIY Videos
3 years agoProgram SiXPIR to Lyric Controller
7 -
14:59
AccAutomation
2 years agoC-More Micro HMI First Program Create
4 -
13:07
AccAutomation
2 years agoC-More Micro HMI First Program Part 2
6 -
27:09
Electrician U
5 years agoHow to Install & Program an Occupancy Sensor - Having Your Lights Turn On/Off Automatically
462 -
10:25
AccAutomation
2 years agoClick PLC Analog Dusk to Dawn Program Example
29 -
26:08
AccAutomation
2 years ago $0.01 earnedC-More Micro HMI Program Quick Start
69 -
10:26
MTandiZ
3 years ago1000 ft Waterproof Doorbell Chime 52 Melodies 5 Volume Levels LED
13 -
1:09:28
Arnold30005
1 year ago🎼🎧Music for Work 🌌 Artificial Intelligence Mix🎧🎼
49 -
6:06
AccAutomation
2 years agoC-More Micro HMI Simulate Project (Simulator)
7