How To Install A Lewden Consumer Unit RCBO Board
In this detailed guide, we'll walk you through the process of installing a Lewden Consumer Unit RCBO Board. Whether you’re a seasoned electrician or a DIY enthusiast with basic electrical knowledge, this step-by-step tutorial will help ensure a safe and effective installation.
Tools and Materials Needed:
Lewden Consumer Unit RCBO Board
Screwdrivers (flathead and Phillips)
Wire strippers
Insulated pliers
Voltage tester
Cable clips
Drill and drill bits (if mounting on a wall)
Appropriate protective gear (gloves, safety glasses)
Step-by-Step Installation Guide:
Preparation and Safety:
Before beginning, turn off the main power supply at the consumer unit and ensure the area is safe to work in.
Use a voltage tester to confirm that there is no power running through the circuit you will be working on.
Remove the Old Consumer Unit (if replacing an existing unit):
Disconnect all circuit wires from the old consumer unit.
Unscrew and remove the old unit from the wall or mounting board.
Mounting the Lewden Consumer Unit:
Position the new Lewden consumer unit on the wall or mounting board.
Mark the drilling points, drill holes, and secure the unit in place with appropriate screws.
Wiring the RCBO Board:
Strip the insulation off the ends of the incoming main supply cables.
Connect the live (brown or red) and neutral (blue or black) wires to the main switch terminals inside the consumer unit.
Secure the earth wire (green/yellow) to the earth bar in the unit.
Install the RCBOs (Residual Current Circuit Breaker with Overcurrent protection) in the allocated slots on the consumer unit.
Connecting Circuit Wires:
Connect the circuit wires to their corresponding RCBOs, ensuring tight and secure connections.
Each RCBO will typically have live, neutral, and earth connections. Follow the manufacturer's wiring diagram for precise connections.
Testing the Installation:
After all connections are made, double-check for tightness and accuracy.
Turn the main power back on and use a voltage tester to ensure that all circuits are correctly energized.
Test each RCBO by pressing the test button to ensure they trip and reset correctly.
Finishing Up:
Neatly organize and secure any loose wires with cable clips.
Replace any covers or panels on the consumer unit and screw them in place securely.
Label the circuits on the consumer unit for easy identification.
Final Checks:
Perform a final inspection to ensure all connections are secure and there are no exposed wires.
Confirm that all safety measures are in place and that the consumer unit is functioning correctly.
Conclusion:
Installing a Lewden Consumer Unit RCBO Board is a task that demands careful attention to detail and strict adherence to safety protocols. By following this guide, you can ensure a reliable and safe electrical installation. Always refer to the manufacturer’s instructions and, if in doubt, consult with a professional electrician.
-
18:01
Tool Box Talk For Electricians
6 months agoElectrifying Christmas Gift Ideas from a Seasoned Electrician!
281 -
LIVE
Ark of Grace Ministries
4 hours agoProphetic Warning: These Eruptions Are All Connected…
2,493 watching -
LIVE
Dr. Drew
4 hours agoEpstein Accuser: Was Diddy A CIA Blackmail Asset? w/ Anouska de Georgiou & Emilie Hagen (LIVE From Sean "Diddy" Combs Trial in Manhattan) – Ask Dr. Drew
433 watching -
LIVE
Redacted News
1 hour agoTucker Carlson WARNS Trump that Neo-cons are trying to END his presidency by going to war with Iran
1,616 watching -
53:32
Kimberly Guilfoyle
2 hours agoThe Fight for Accountability, Live with Martha Byrne & Daniel Turner | Ep227
19.8K3 -
LIVE
The Officer Tatum
2 hours agoLIVE: Elon Musk DROPS BOMB On Donald Trump + MORE | EP 118
1,287 watching -
1:46:26
Roseanne Barr
2 hours agoDon't Let Commies Split Maga W/ James Lindsay | The Roseanne Barr Podcast #102
39.8K14 -
1:20:08
Untamed Nation
1 hour agoIS THE BROMANCE DEAD?? BIG BEAUTIFUL BILL MELTDOWN | 5 JUNE 2025
11.9K -
DVR
freecastle
6 hours agoTAKE UP YOUR CROSS- RESTORING ORDER AT OUR SOUTHERN BORDER
1226 -
LIVE
Tommy's Podcast
1 hour agoFallout Cast | James Kunstler, Dave Collum, Tom Luongo (TPC #1,762)
560 watching