Safely Charge A2L Refrigerant Systems with YELLOW JACKET® Tank Adapters & Charging Hoses
The new A2L refrigerants, R-32 and R-454A, have adopted left-handed connections for their tanks. These new refrigerants are categorized as slightly flammable, so left-handed connections were implemented to differentiate them from A1, non-flammable refrigerants. The YELLOW JACKET® A2L Tank Adapters and Charging Hoses incorporate left-handed connections so a service technician can safely charge A2L refrigerant systems.
To learn more, visit: https://yellowjacket.com/product/a2l-adapters-and-hoses/
16
views
Combustion Analyzer Set Up Instructions
Learn how to set up your YELLOW JACKET® Combustion Analyzer CA502 and CA502P for first time use and for changing settings as needed. See the Combustion Analyzer IN USE video for a demonstration of the product in use with wireless printer.
Learn More:
https://yellowjacket.com/product/combustion-analyzer/
37
views
The 3-IN-1 Combustion Analyzer for Safe, Accurate Diagnostics
The YELLOW JACKET® Combustion Analyzer CA502 delivers ambient CO and flue gas monitor, manometer and analyzer functionality in one compact tool. Includes two gas sensors for O2, (oxygen) and CO (carbon monoxide). Two-minute efficiency testing and rapid reporting via the app and printed using the optional wireless Bluetooth® printer.
21
views
The TWO-IN-ONE ADVANTAGE with YJACK MANO™
Learn how the YJACK MANO™ Wireless Dual Port Manometer by YELLOW JACKET® combines wireless and stand-alone manometers into one compact device. Check readings on local display or via Bluetooth with the FREE YJACK VIEW app. The app records all YJACK data in customizable service reports for total system analysis.
10
views
The 3-IN-1 Combustion Analyzer for Safe, Accurate Diagnostics.
The YELLOW JACKET® Combustion Analyzer CA502 delivers ambient CO and flue gas monitor, manometer and analyzer functionality in one compact tool. Includes two gas sensors for O2, (oxygen) and CO (carbon monoxide). Two-minute efficiency testing and rapid reporting via the app and printed using the optional wireless Bluetooth® printer.
https://yellowjacket.com/product/combustion-analyzer/
9
views
ManCover™ for Manifold Protection
The YELLOW JACKET® ManCover™ P/N 49095 provides protection for your most trusted testing instruments. Durable rubber material provides ‘bounce’ protection in the van and on the jobsite. Gauge faces are protected from damage while the large opening allows hoses to remain connected. The hook slot makes it easy to slip the cover over most manifolds for hanging in the van or on the jobsite (see the Magnetic Hook P/N 61193). ManCover™ protects the YELLOW JACKET® TITAN®, BRUTE®, BRUTE II®, Series 41 Manifolds and many other manifolds.
More information at: https://yellowjacket.com/product/mancover/
11
views
YJACK MANO by YELLOW JACKET
Take accurate static pressure measurements up to +/- 80 inches of water column with the YJACK MANO™ Wireless Dual Port Manometer 67068 by YELLOW JACKET®. Measure pressure drop across a filter or Total External Static Pressure (TESP) with the included static pressure tips. Measure gas pressure at the regulator inlet and outlets with the 1/8” NPT fitting or slide gas adapter. Use the integrated display to view the system readings or view and analyze all the system measurements with the YJACK VIEW® app. Soft case included for convenient storage of manometer and adapters.
17
views
YJACK VIEW App Static Pressure Session 22-5
YJACK VIEW App Static Pressure Session using YJACK NO
11
views
YJACK VIEW App Report Generation 22-5
YJACK VIEW App Report Generation for YJACK Wireless Probe Series Products
10
views
YJACK VIEW App Psychrometric System Efficiency Session 22-5
YJACK VIEW App Psychrometric System Efficiency Session using YJACK DEW.
5
views
YJACK VIEW App Pressure Temperature Session 22-5
YJACK VIEW App Pressure Temperature Session using YJACK PRESS, Clamp, Strap and P51-870
9
views
YJACK VIEW App Leak Test Session 22-5
YJACK VIEW App Leak Test Session using YJACK PRESS and P51-870
7
views
YJACK VIEW App General Settings 22-5
YJACK VIEW App General Settings for YJACK Wireless Probes Series
13
views
YJACK VIEW App Evacuation Session 22-5
YJACK VIEW App Evacuation Session using YJACK VAC 67066 and P51-870.
5
views
YJACK VIEW App Electrical Session 22-5
YJACK VIEW App Electrical Session using the YJACK AMP 67067
6
views
YJACK VIEW App Charge Recovery Session 22-5
YJACK VIEW App with Wireless Refrigerant Scale 68864 demonstration.
6
views
YJACK All Graphic Video 22-2
YELLOW JACKET Graphic Video Showcasing the YACK Series Wireless Sensors
7
views
Refrigerant Recovery with TurboRecover, Wireless Scale and P51-870
YELLOW JACKET continues to innovate with the introduction of one of the fastest refrigerant recovery machines in the market. This video demonstrates the superior features and speed of the YELLOW JACKET 95780 TurboRecover Recovery Machine used in conjunction with the 68864 Wireless Refrigerant Scale while recovering refrigerant from a commercial rooftop unit.
TurboRecover Information: yellowjacket.com/product/turborecover-recovery-machine/
For more details, visit yellowjacket.com
38
views
HVAC System Evacuation with YJACK VAC and YJACK VIEW App
Using a digital vacuum gauge that is reliable and accurate is key to proper evacuation on every job. One that also offers the flexibility to monitor the evacuation status remotely allows for even more efficient system evacuation. This video demonstrates the key features of the 67066 YJACK-VAC Vacuum Gauge while performing a fast and effective evacuation of a commercial rooftop unit.
YJACK VAC Vacuum Gauge Information: yellowjacket.com/product/yjack-vac-vacuum-gauge/
For more details, visit yellowjacket.com
18
views
HVAC System Evacuation with YELLOW JACKET BULLET DC and YJACK VAC
System evacuation is one of the most important processes in HVAC service. This video demonstrates how the YELLOW JACKET 93870 Bullet DC Vacuum Pump and the 67066 YJACK VAC Vacuum Gauge were used to perform a fast and effective evacuation of a commercial rooftop unit.
YJACK VAC Information: yellowjacket.com/product/yjack-vac-vacuum-gauge/
Bullet DC Information: yellowjacket.com/product/bulletdc-vacuum-pump/
For more details, visit yellowjacket.com
22
views
Electrical Current Measurements with YJACK AMP and YJACK VIEW App
System electrical measurements are an important part of determining a systems energy efficiency and can also be used to troubleshoot system electrical problems. This video demonstrates how the YELLOW JACKET 67067 YJACK AMP Current Probe is used to check a system’s electrical measurements and overall efficiency.
YJACK AMP Information: yellowjacket.com/product/yjack-amp-current-probe/
For more details, visit yellowjacket.com
15
views
Charging R-290 System with YELLOW JACKET Hydrocarbon Charging Kit
Hydrocarbon refrigeration systems require unique charging equipment due to their critical charge amounts and refrigerant flammability. This video demonstrates how the YELLOW JACKET 61001 Hydrocarbon Charging Kit can be used to safely and effectively charge an R-290 reach-in cooler.
Hydrocarbon Charging Kit Information: yellowjacket.com/product/hydrocarbon-charging-kit/
For more detail, visit yellowjacket.com
20
views
Pressure Temperature Check with YJACK PRESS and YJACK Temp Clamps
Wireless probes make it easy to take accurate system pressure and temperature readings, critical for proper system diagnostics. This video demonstrates how the YELLOW JACKET YJACK PRESS and YJACK Wireless Temperature Probes broadcast the system readings right to your smartphone or tablet.
YJACK PRESS Information: yellowjacket.com/product/yjack-press-pressure-gauge/
YJACK Temperature Clamp Information: yellowjacket.com/product/yjack-temperature-clamp/
For more details, visit yellowjacket.com
9
views
TurboRecover Recovery Machine Graphic Video
The YELLOW JACKET TurboRecover has all the features you need for fast and effective refrigerant recovery. The powerful twin-cylinder, oil-less compressor and 1.25 hp Brushless DC (BLDC) motor ensure fast recovery of every system. Lightweight design and included shoulder strap allow for easy transportation to any jobsite. The single control valve and status indicator LED make it the simplest recovery machine on the market!
Dual-gauge design allows for monitoring of the system and tank pressures simultaneously and integrated low-pressure switch automatically powers down the machine when the system reaches 10” of vacuum. Integrated purge circuit clears residual refrigerant from the machine, preventing cross-contamination when changing from one refrigerant to another. The reusable mesh particulate filter is integrated into the suction port and can be easily cleaned or replaced. TurboRecover includes all of these great features to make your job easy.
TurboRecover Information: yellowjacket.com/product/turborecover-recovery-machine/
For more details, visit yellowjacket.com
9
views
YELLOW JACKET BULLET DC Vacuum Pump Graphic Video
Light in Weight, Heavy in Value.
The Brushless DC (BLDC) Motor incorporated in the next generation BULLET DC Vacuum Pump provides key advantages over existing AC technology vacuum pumps. High torque and high efficiency define the ultimate performance in the most reliable vacuum pump. Able to function in extreme low voltage conditions and field rated to 25 microns, the BULLET DC is the perfect combination of quality and value. The easy to carry, lightweight design is available in 7 cfm to handle most residential and commercial applications. Pulling down to less than 25 microns, BULLET DC protects the system from contaminants and non-condensable gases, which can damage components, reduce efficiency and cause system failure.
Optional Shoulder Strap (PN 92965) for easy transporting to job sites.
Bullet DC Vacuum Pump Information: yellowjacket.com/product/bulletdc-vacuum-pump/
For more details, visit: yellowjacket.com
35
views