Programming the 5800COMBO to the L7000 Panel
In this video, Jorge shows users how to program a Honeywell 5800COMBO to a Honeywell L7000 Panel. The 5800COMBO is a multi-purpose life-safety device that responds to smoke, heat and deadly carbon monoxide gas. It also includes a built-in freeze detector for responding to unusually low temperatures.
In order to get full functionality out of a Honeywell 5800COMBO, it will need to be programmed to multiple system zones. Each zone will serve a different purpose for the sensor, and each is necessary for achieving complete device functionality. However, if a user does not require a certain function of the 5800COMBO, then they will not have to program for that zone. In total, the sensor can use up to five zones on the L7000. These are smoke/heat detection, CO detection, low-temperature detection, supervision and end of product life.
The heat sensor inside the 5800COMBO is a fixed-temperature device that activates at 135 degrees Fahrenheit. There is no rate of rise temperature in the 5800COMBO. The smoke detector is a photoelectric sensor that activates when an internal light is refracted due to airborne particles. To prevent false alarms, an infrared (IR) sensor will scan the area for ambient light levels and other signs of a fire, such as flame flickers. The CO sensor responds to unusual high levels of CO gas that could cause serious harm or death. The low temperature sensor responds at 41 degrees or lower.
The two other zones on the 5800COMBO are for supervision and end of product life. Supervision involves having the panel listen for RF check-in signals that make sure the device is live and within signal range. End of product life is ten years, at which point the CO detector will stop working, and the device will need to be replaced. The sensor also has two test buttons for testing the smoke/heat and CO detection sensors respectively. There's also a built-in 85 dB sounder for alerting those to a life-threatening situation.
Note: When Jorge mentions enabling supervision in zone programming, he incorrectly mentions that this enables tamper and low battery supervision. However supervision for these conditions is always enabled. Supervision actually refers to the panel listening for RF check-in signals from the device and alerting the user if enough check-in signals are absent within a period of time.
-
10:19
Alarm Grid Home Security DIY Videos
1 year agoPROA7 or PROA7PLUS: Awareness Zone Types
34 -
DVR
vivafrei
9 hours agoLive w/ Stanislav Krapivnik - Military and Political Analyst on Russia, Europe & Beyond!
44.2K18 -
LIVE
LadyDesireeMusic
1 hour agoYour Daily White Pill- Music & Convo
100 watching -
LIVE
StoneMountain64
5 hours agoBattlefield REDSEC UNSTOPPABLE WIN Squad
68 watching -
1:40:36
The Quartering
5 hours agoKimmel Pulls Show Mysteriously, Youtube Collapse? & Much MOre
98.5K58 -
LIVE
cosmicvandenim
5 hours agoCOSMIC VAN DENIM | OFF CHARACTER | WARZONE PRACTICE
79 watching -
2:08:06
The Robert Scott Bell Show
5 hours agoMike Adams, Brian Hooker, Live From Brighteon Studios in Austin Texas, Kids Triple Vaccinated, Blood Sugar and Autism, Candy Fed to Cows, Nutrition Reform - The RSB Show 11-7-25
30.8K7 -
LIVE
GritsGG
4 hours ago#1 Most Warzone Wins 3943+!
26 watching -
1:15:58
DeVory Darkins
6 hours agoLIVE NOW: Democrats SABOTAGE GOP effort to reopen Government
108K61 -
1:21:21
Tucker Carlson
5 hours agoThe Global War on Christianity Just Got a Whole Lot Worse, and Ted Cruz Doesn’t Care
63.2K263