Using the 5800COMBO With the Lyric Alarm System
In this video, Jorge talks about using the Honeywell 5800COMBO with the Resideo Lyric Security System. The Lyric supports 345 MHz 5800 Series Sensors like the 5800COMBO. The sensor will take up five (5) zones for maximum functionality. You don't need to program for functions you do not want to use.
The Honeywell 5800COMBO is what is known as a combination life-safety sensor. It looks for smoke, heat, low-temperature, and carbon monoxide gas. Whenever the sensor senses one of these conditions, it will send an alert to the security system to let it know about the situation. The system will then respond based on the programming settings for that wireless zone. Each detection function will need to have its own zone on the system.
If you program every function available for the 5800COMBO, the single sensor will take up five (5) zones. These zones are for smoke/heat detection, low-temperature detection, CO detection, maintenance detection, and end of product life detection. But you only need to program the sensor for the functions you want to use. Each zone will have a different Loop Number and Serial Number combination. There are actually two Serial Numbers used with the 5800COMBO. The second SN is one digit higher. For example, if the first SN is 1234567, the second will be 1234568.
The 5800COMBO is extremely versatile and convenient. Many users love the fact that they can get reliable smoke detection and CO detection out of one device. This saves space on the wall or ceiling, and makes it easier if you ever have to remount or replace the sensor. Keep in mind that you will need to test the sensor for both smoke/heat and CO detection capabilities. The 5800COMBO has two (2) separate test buttons for this purpose.
Pelase note that the Freeze detection activation will not be sent to the alarm panel immediately upon being triggered. These signals will be piggy-backed onto the next supervision check-in signal. For this reason, it can be up to 90 minutes from the time a free warning is activated by the 5800COMBO, and when it is transmitted to the system.
-
3:39
Alarm Grid Home Security DIY Videos
1 year agoQolsys IQ Panel 4: Using Dual Path Monitoring
21 -
4:00:19
The Bubba Army
1 day agoAnother LopSided Jake Paul Fight? - Bubba the Love Sponge® Show | 8/21/25
88.1K1 -
1:02:42
Dialogue works
1 day ago $4.43 earnedJohn Helmer: Trump Ditches Ceasefire? Despite EU & Zelensky Pressure
62.4K22 -
10:48
Nikko Ortiz
21 hours agoDont Watch These TikToks
94.6K14 -
10:17
MattMorseTV
20 hours ago $16.59 earnedTrump's DOJ just DROPPED a NUKE.
96.9K104 -
2:09:32
Side Scrollers Podcast
23 hours agoStreamer DIES Live On Air + Your Food is Poison + Xbox Announces $900 Handheld | Side Scrollers Live
51K19 -
15:32
GritsGG
19 hours agoFull Auto ABR Sniper Support! Most Winning Quad Win Streaking!
36.1K4 -
7:42
The Pascal Show
18 hours ago $2.39 earnedBREAKING! Police Provide UPDATE In Emmanuel Haro's Case! Is Jake's Lawyer Lying To Us?!
42.5K2 -
2:29:46
FreshandFit
11 hours agoAfter Hours w/ Girls
147K95 -
5:28
Zach Humphries
17 hours ago $2.84 earnedNEAR PROTCOL AND STELLAR TEAM UP!
42.5K4