Premium Only Content

Adding Hardwired Zone to DSC PowerSeries NEO Security System
In this video, Michael from Alarm Grid shows you how to add a hardwired zone to a DSC PowerSeries NEO Security System. As a hardwired security panel, the DSC PowerSeries NEO can readily support wired sensors.
Every wired zone on the DSC PowerSeries NEO must have an end of line resistor (EOLR). This includes zones that are not actively being used. Any wired zone without an end of line resistor will be displayed as open. The resistor value to use is a 5.6k ohm resistor, which is color coded green, blue, red, gold. These resistors come included with the panel. Normally Closed (NC) sensors use a resistor that is wired in series. Normally Open (NO) sensors use a resistor that is wired in parallel.
When you wire a sensor to the NEO, you are essentially choosing which zone the sensor will use. Conventional hardwired sensors are not enrolled with the NEO using a serial number. The system simply sees the zone, and it responds accordingly when the connected sensor is faulted. How the system responds depends upon the Zone Definition that has been set for the zone. You need to go into programming and set each Zone Definition accordingly. Every possible Zone Definition option has its own 3-digit code that is used for assignment purposes. Enter the 3-digit code in the appropriate programming field to configure a zone with the proper definition. You can see a complete list of all the possible Zone Definitions in the reference manual that comes included with the NEO.
Remember that some hardwired sensors will only require a 2-wire connection, while others will utilize a 4-wire connection. A sensor that uses a 2-wire connection is strictly sending zone status transmissions (open or closed) to the panel. When a sensor uses a 4-wire connection, it uses 2 wires for zone status, and 2 wires for power. In other words, a 4-wire sensor will draw a small amount of current from the sensor, while a 2-wire sensor is simply a mechanical device that will not draw any electrical current from the panel.
https://www.alarmgrid.com/faq/how-do-i-program-a-hardwired-zone-to-a-dsc-powerseries-neo
-
6:05
Alarm Grid Home Security DIY Videos
1 year agoPROA7 or PROA7PLUS: Using Lyric Sensors
22 -
DVR
VINCE
2 hours agoThe Left's 'Malignant' Violence Problem | Episode 126 - 09/16/25
72.1K28 -
LIVE
Benny Johnson
1 hour agoKash Patel Testifying LIVE Now on Charlie Kirk Assassination, Trump to Declare Antifa TERRORISTS?!
6,062 watching -
LIVE
LFA TV
4 hours agoLFA TV ALL DAY STREAM - TUESDAY 9/16/25
4,394 watching -
1:45:59
Dear America
2 hours agoKiller ADMITS To Killing Charlie In DISCORD. Terror Cell EXPOSED! + JD Fills In on Charlie’s Show!
131K77 -
LIVE
Wendy Bell Radio
6 hours agoThe Left Lives In A Bubble
7,572 watching -
LIVE
Barry Cunningham
1 hour agoLIVE BREAKING NEWS: KASH PATEL HEARING!
1,855 watching -
LIVE
House Committee on Energy and Commerce
47 minutes agoAppliance And Building Policies: Restoring The American Dream Of Home Ownership And Consumer Choice
80 watching -
LIVE
The Big Migâ„¢
2 hours agoTrump Declares Antifa Is A Domestic Terrorist Organization
2,568 watching -
LIVE
Badlands Media
6 hours agoBadlands Daily: September 16, 2025
3,179 watching