DSC PG9905: Programming to Qolsys IQ Panel 2 Plus
In this video, Michael from Alarm Grid shows you how to program the DSC PG9905 PowerG Temperature Sensor to the Qolsys IQ Panel 2 Plus Security System. Like most PowerG Sensors, the PG9905 is readily supported by all versions of the Qolsys IQ Panel 2 Plus. This sensor is designed to alert the system whenever the detected temperature goes outside a set threshold, typically because the HVAC system inside the building has stopped working.
You can configure the PG9905 for high temperature monitoring and/or low temperature monitoring. But there is one major restriction associated with this sensor. If you have configured the wireless zone so that the system will report out to Alarm.com upon the sensor being activated, then you will only be able to use the sensor for either low temperature monitoring or high temperature monitoring. The only way you can use both high temperature monitoring and low temperature monitoring with one single PG9905 Sensor is if you configure the zone so that the system will not report out to Alarm.com and only provide local alerts at the panel.
However, most users will want to have the system report out to Alarm.com, so you will likely need to choose whether low temperature or high temperature monitoring is needed. Of course, you can always reprogram the associated zone for the PG9905 to either low temperature monitoring or high temperature monitoring depending on the time of year. This can prevent you from needing to buy a second PG9905 Sensor.
When you go to program the zone, you will also set the low and/or high temperature thresholds that will determine when the sensor should notify the system. If the zone is configured so that the system will report out, then this will also determine when you are ultimately notified by Alarm.com regarding an unusually high or low temperature. High temperature monitoring can be crucial in the summer months for ensuring that you arrive home to a comfortable house, while low temperature monitoring is important in the winter months for ensuring that the pipes inside the building do not freeze.
https://www.alarmgrid.com/faq/how-do-i-program-a-dsc-pg9905-temperature-sensor-with-a-qolsys-i
-
10:19
Alarm Grid Home Security DIY Videos
1 year agoPROA7 or PROA7PLUS: Awareness Zone Types
32 -
2:05:53
Inverted World Live
4 hours agoDeath Cult Terror Cells, NASA Bans Chinese Nationals | Ep. 108
47.6K6 -
2:43:57
TimcastIRL
5 hours agoVP Says No Unity With Democrats Celebrating Charlie Kirk Assassination, Left Confirmed | Timcast IRL
248K142 -
13:45
The Charlie Kirk Show
4 hours agoTPUSA AT ASU CANDLELIGHT VIGIL
206K37 -
55:10
Katie Miller Pod
4 hours ago $8.05 earnedEpisode 6 - Attorney General Pam Bondi | The Katie Miller Podcast
62.9K20 -
1:46:41
Man in America
9 hours agoLIVE: Assassin Story DOESN'T ADD UP! What Are They HIDING From Us?? | LET'S TALK
46.3K42 -
2:24:17
Barry Cunningham
5 hours agoFOR PRESIDENT TRUMP WILL TAKE NO PRISONERS AND THE LIBS SHOULD EXPECT NO MERCY!
85.5K59 -
1:08:41
Savanah Hernandez
6 hours agoCharlie Kirk Was Our Bridge And The Left Burned It
42.3K40 -
1:59:01
Flyover Conservatives
8 hours agoFinancial Web Behind Charlie Kirk's Murder with Mel K | Silver On It's Way to $50 | FOC Show
55.4K3 -
2:36:19
We Like Shooting
16 hours ago $1.01 earnedWe Like Shooting 628 (Gun Podcast)
37.3K