Premium Only Content

Generac 16kW generator - second start after valve adjustment
This video shows the second startup of our 16kW NG Generac generator (model 0052540, serial 4643547) after adjusting the valves. The exhaust valves were tight (no lash clearance, basically), so I adjusted them to 0.003" and also set the intake valves to 0.003". The spark plugs were also checked, but their gaps were pretty much right at 0.040".
Earlier, I had replaced the stepper motor/controller and set the choke plate return spring arm in its proper location in order to fix an Overspeed and Hard Starting problem with the generator. The generator would start, but it was still struggling (see this video for comparison: https://rumble.com/v5l65gw-generac-16kw-generator-startup-after-stepper-motor-and-choke-plate-repairs.html ), but after also adjusting the valves you can see that the generator start so much easier!
-
LIVE
DLDAfterDark
4 hours agoThe Return of Marine Gun Builder? MGB, DLD, BDG&G After Hours Armory
194 watching -
28:39
Afshin Rattansi's Going Underground
1 day agoDonald Trump’s Gaza Peace Plan: A Pivotal Moment or Farce? (Palestinian Deputy Foreign Minister)
17.9K6 -
3:31:29
SavageJayGatsby
5 hours ago🔥 Spicy Saturday – Let's Play: Prison Life 2🔥
29.4K2 -
4:34:18
cosmicvandenim
11 hours agoCOSMIC VAN DENIM | WARZONE HORROR
9.1K1 -
29:09
Stephen Gardner
9 hours ago🚨Trump DECLARES WAR on TERRORIST LEFT!
23.8K40 -
NellieBean
4 hours ago🔴 Lost Girl looks for Lost Village
5.33K -
30:07
JohnXSantos
1 day agoWhy Clothing Brands NEVER Fail- Master Class
5.23K -
LIVE
Spartan
3 hours agoOMiT Spartan | God of War Ragnarok, College Halo match @ 9:30 EST, then ranked or more GoW:R
10 watching -
DVR
John_Goetz
2 hours agoJohn Gets Gaming - Ghost of Yotei
1.72K -
2:48:33
AgnoLand
3 hours ago[LIVE] Battlefield 6 | Full Focus, Cinematic Moments, Zero Fear 😎
1.39K