Wireless Repeater: Use With Life Safety Devices
In this video, Dylan from Alarm Grid technical support discusses using wireless life safety devices with a repeater. For the repeaters and the systems we support, unless otherwise specified in either the repeater or the sensor documentation, any wireless life-safety device that uses the same protocol as the repeater is supported by the repeater.
Life-safety devices, for the purposes of this video, consist of smoke detectors, and carbon monoxide sensors. Heat detectors are not technically life-safety sensors, but since they operate and program just like smoke detectors, we often erroneously lump them into this category.
The two main repeaters we support are the Resideo (formerly Honeywell) 5800RP and the DSC PG9920. The 5800RP supports sensors that use the 345 MHz frequency made popular by Honeywell systems. The DSC PG9920 supports DSC and Qolsys PowerG sensors, which use 915 MHz as their frequency. In either case, these repeaters will repeat signals for life-safety devices if the repeater picks up the signal.
A sensor signal can only be repeated one time. So, for example, if you're using a 5800RP with a compatible sensor, that sensor by itself has a transmitting range of about 200 feet in open air. By adding a repeater, you can effectively extend that range to 400 feet. However, you can't then add another repeater beyond the first one and extend the range to 600 feet. A repeater can't repeat a signal that has already been repeated.
The real question comes when you consider agency listings such as UL, ETL, Factory Mutual (FM), and the California State Fire Marshall (CSFM). Any of these agencies may have restrictions in place that would prevent the use of a repeater with a life-safety device, in spite of the fact that the life-safety device may actually benefit from the use of the repeater. In these cases, it is up to the agency having jurisdiction (AHJ) whether you are permitted to use a repeater or not. The documentation for the repeater and the life-safety sensor should have any restrictions for their use outlined in a section specifically devoted to agency restrictions. Please refer to the FAQ linked at the bottom of this description for more information.
https://www.alarmgrid.com/faq/can-you-use-life-safety-devices-with-a-repeater
-
3:39
Alarm Grid Home Security DIY Videos
2 years agoQolsys IQ Panel 4: Using Dual Path Monitoring
21 -
2:43:41
Side Scrollers Podcast
19 hours agoAsmongold Says The Online Left Are “ANIMALS” + Hasan Collar-Gate Gets WORSE + More | Side Scrollers
20.9K15 -
1:33:41
Dinesh D'Souza
2 days agoThe Dragon's Prophecy Film
89.7K58 -
LIVE
Lofi Girl
2 years agoSynthwave Radio 🌌 - beats to chill/game to
337 watching -
44:08
The Why Files
6 days agoThe CIA, Men in Black and the Plot to Take Out JFK | The Maury Island Incident
53.7K66 -
2:07:23
TimcastIRL
10 hours agoTrump SLAMS China With NEW 100% Tariff, Stocks & Crypto TUMBLE | Timcast IRL
302K161 -
5:15:25
SpartakusLIVE
11 hours agoBF6 LAUNCH DAY || WZ and BF6 followed by PUBG - The PERFECT Combo?
66.1K3 -
1:33:59
Glenn Greenwald
13 hours agoQ&A with Glenn: Is the Gaza Peace Deal Real? Why was the Nobel Peace Prize Given to Venezuela's Opposition Leader? And More... | SYSTEM UPDATE #529
119K73 -
1:24:01
Flyover Conservatives
1 day agoURGENT FINANCIAL UPDATE! October 14–31: The Great and Terrible Day Has Arrived - Bo Polny; 5 Mindsets You Must Master - Clay Clark | FOC Show
58.2K5 -
4:01:36
VapinGamers
9 hours ago $7.72 earnedBattlefield 6 - All Protatoe and Nothing but Net - !rumbot !music
40.5K1