how to fix error DHPFKB Rear Pump short circuit ??? check it first !!!
error DHPFKB caused Signal voltage from rear pump pressure sensor increased to 4.5 V or above.
Action of
controller
:
- Fixes travel speed to Lo.
- Continues controls, assuming pressure to be constant {350 kg/cm2}.
- Even if cause of failure disappears, machine does not become normal starting switch is turned to
OFF position.
Problem on
machine
- Rear pump pressure cannot be monitored.
-Travel and work equipment speeds are insufficient.
Related
information
- As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be measured at pump controller connector.
- Input voltage from rear pump pressure sensor can be checked by using monitoring function.
(Code: 01113 Rear pump pressure sensor voltage)
-Method of reproducing failure code: Turn starting switch to ON position or start engine.
-
31:44
SouthernbelleReacts
2 days ago $0.30 earned“E.T. Phone Home! 🛸 Emotional Mom Style Reaction to E.T. the Extra-Terrestrial (1982)”
4.15K1 -
20:10
JohnXSantos
22 hours agoI Built a FAKE Luxury Brand With $100 In 7 Days
2.54K -
25:24
marcushouse
2 hours ago $0.42 earnedStarship Test Trouble… and Block 3 Finally Unveiled! 🤯
3.84K2 -
1:13:26
Squaring The Circle, A Randall Carlson Podcast
8 hours agoSaving The Bees and Healing The Planet!
2.82K1 -
16:18
Chris Harden
2 days agoCharlie Kirk Utah Reaction | What Locals Are Saying
4K3 -
50:47
ChurchandState1776
18 hours agoFree speech is not negotiable with Sam Anthony
2.23K2 -
LIVE
Total Horse Channel
19 hours agoAMHA 2025 9/20
970 watching -
16:59
Chris From The 740
19 hours ago $2.43 earnedIs Bigger Better? - The Gideon Optics Mediator 2 Is Here!
16K1 -
7:58
Blackstone Griddles
15 hours agoTennessee Mountain Burgers on the Blackstone Griddle
17.8K3 -
43:32
NAG Daily
16 hours agoThe Rezendes Rundown Ep. 17 - Epstein's Birthday Book
14.1K6