Testing the 3 - 20P battery modules removed from service after 1.5 - 2.5 years of daily use.

Months Start/AH End/AH Loss-%/mo
29 32.8 29.3 0.37
26 35.1 33.9 0.13
18 35.1 32.4 0.43

The average is 0.31%/mo. or around 4%/yr. Testing temperatures may have been different between the 3 modules and affected the results. A sample size of 3 is not good at drawing general conclusions, but it seems the used laptop cells fair as well as the new BAK cells, at least one of those two modules.