Terminating Wire in a Round Box
3 years ago
4
Electric Pro Academy - Real Skills to make real money.
- After running wires the job site is turned over to drywall and paint. If you don't correctly manage your wires inside the box it is highly probable that the drywall installers will tear up your wires with their wallzip tools. Then on finishout you will have to spend more time repairing and possibly even re-running wire wasting your time and money
- Leave 9 inches of cable inside the box.
- Fold don't stuff your wires
Got a question or ideas for a video leave and comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3
Loading comments...
-
5:35
EPro - Electric Pro Academy
3 years agoTerminating Wire In a 3 Gang Switch Box
16 -
7:10
EPro - Electric Pro Academy
3 years agoInstalling New Work Boxes & Wire Terminations
10 -
6:36
Electrician U
1 year agoSTOP Cutting Wires So Short!!! What Does Code Say?
193 -
0:57
toolboxtalksforelectricians
4 months agoHow Easy To Pull Cables as a Electrician #shorts #electricianlife #electrician
7 -
5:26
TravelingCraneWoodcrafts
2 years agoElectrical Box Cover
11 -
0:49
Top Homeowner
1 year agoThe Ultimate Solution for Hiding TV Wires - echogear In Wall Cable Management Kit #shorts
3 -
7:23
Ultimate Tech Hub
2 years agoCAT6 CABLE RUN THROUGH WALL AND ETHERNET JACK INSTALL - HOW TO
205 -
10:53
DIOTV
10 months agoHow To Reroute Coax Cable Wire
14 -
6:22
Electrician U
2 years agoHow Many Wires Can Fit in Each Hole?
92 -
3:18
Chris Green Music
8 months agoA Practical Cable Management Solution: Startech Raceway Duct
22